WORKING PRINCIPLE


  • The gas is accelerated in the venturi. The liquid is sprayed just above the throat of the venturi covering the entire gas path.

  • The contaminants impact on the finely sprayed droplets and become heavier.

  • The gas and liquid flow concurrently downwards into a cyclonic mist eliminator.

  • The heavier contaminant particles are separated by centrifugal action in the cyclone.

  • The clean gas leaves the cyclones from the top and is exhausted through I.D. Fan to chimney/stack.

  • The I.D. Fan provides the necessary gas flow at designed pressure drop.

  • The scrubbing liquid separated from cyclone is collected in the circulating tank.

  •  The liquid passes through filter where solids get separated and liquid is given to circulating pump.

  • The circulating pumps the liquid to nozzle for atomization.

  • The systems can be manual or fully automatic.