Wet Ventury Scrubbers :
WORKING PRINCIPLE
The gas is accelerated in the venturi. The liquid is sprayed just above the throat of the venturi covering the entire gas path.
The contaminants impact on the finely sprayed droplets and become heavier.
The gas and liquid flow concurrently downwards into a cyclonic mist eliminator.
The heavier contaminant particles are separated by centrifugal action in the cyclone.
The clean gas leaves the cyclones from the top and is exhausted through I.D. Fan to chimney/stack.
The I.D. Fan provides the necessary gas flow at designed pressure drop.
The scrubbing liquid separated from cyclone is collected in the circulating tank.
The liquid passes through filter where solids get separated and liquid is given to circulating pump.
The circulating pumps the liquid to nozzle for atomization.
The systems can be manual or fully automatic.