The gas is accelerated in the venturi. The liquid is sprayed just above
the throat of the venturi covering the entire gas path.
-
The contaminants impact on the finely sprayed droplets and become heavier.
-
The SO2 reacts with the alkaline solution and gets consumed.
-
The gas and liquid flow concurrently downwards into a cyclonic mist
eliminator.
-
The heavier contaminant particles and precipitated reacted particles are
separated by cen
-
The gas to be scrubbed is introduced in the venturi and scrubbed by
alkaline liquid solution.
-
trifugal action in the cyclone.
-
The clean gas leaves the cyclone from the top and is exhausted through
I.D. Fan to chimney/stack.
-
Back pressure control loop ensures constant pressure for smooth running of
the equipment on which desulphurization system is installed.
-
The I.D. Fan provides the necessary gas flow at designed pressure drop.
-
The scrubbing liquid separated from cyclone is collected in the
circulating tank.
-
The pH of scrubbing liquid falls down as alkali is consumed.
-
The pH control loop provided senses the pH continuously and intakes the
fresh alkaline solution to maintain the pH.
-
The water if evaporated by the hot gases is made up by tank level control
loop.
-
The liquid passes through filter where solids get separated and liquid is
given to circulating pump.
-
The circulating pump pumps the liquid to nozzle for atomization.
The system can be semi-automatic or fully automatic as
per requirement and are explained subsequently.