Bag Filters :

How Ecokleen Bag Filter and Cyclone cum Bag Filter pays for itself?

  • Ecokleen Bag Filter: 

    »          The pressure drop across Ecokleen Bag Filter is 100 mm WC while  that of a  
                conventional  Bag  Filter is 150 mm WC.
    »          Thus Ecokleen reduces the load on fan by 50 mm WC.
    »          Table below gives the power savings for different airflow rates. 

    Sr.No.

    Gas flow rate (m3/hr)

    Power saved per hour (kWh)

    Power saved per annum (kWh)

    Savings per annum (Rs)

    1.         

    1,000

    0.21

    1,680

    6,972/-

    2.         

    5,000

    1.05

    8,400

    34,860/-

    3.         

    10,000

    2.10

    16,800

    69,720/-

    4.         

    15,000

    3.15

    25,200

    1,04,580/-

    5.         

    20,000

    4.20

    33,600

    1,39,440/-

    Note: »          Working hours per year considered is 8000
             »          Electricity tariff rate considered is 4.15 Rs/kWh 

     

  • Ecokleen Cyclone cum Bag Filter:

     »          The total pressure drop across Ecokleen cyclone cum bag filter is typically 125 mm 
                 WC. The total pressure drop across conventional cyclone is 100 mm WC and across 
                 bag filter is 150 mm WC – totalling to 250 mm WC.
    »           Thus Ecokleen reduces the load on fan by 125 mm WC.
    »           Table below gives the power savings for different airflow rates. 

    Sr. No.

    Gas flow rate (m3/hr)

    Power saved per hour (kWh)

    Power saved per annum (kWh)

    Savings per annum (Rs)

    6.         

    1,000

    0.52

    4,192

    17,398/-

    7.         

    5,000

    2.60

    20,800

    86,320/-

    8.         

    10,000

    5.20

    41,920

    1,73,980/-

    9.         

    15,000

    7.80

    62,400

    2,58,960/-

    10.    

    20,000

    10.40

    83,840

    3,47,936/-

    Note:  »          Working hours per year considered is 8000 
              »         
    Electricity tariff rate considered is 4.15 Rs/kWh
     